Compex-systems Advanced SerialRAID Adapters SA33-3285-02 Instrukcja Użytkownika Strona 377

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 531
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 376
-S b[card ...]
Resets the flag for the bypass card. Valid values for card are 1, 4, 5, 8, 9, 12,
13, 16.
-S p[PSU ...]
Resets the flag for the selected PSU (power supply assembly). Valid values for
PSU are 1, 2.
-S r Resets the flag for remote power on (RPO).
-S c Resets the flag for the controller card.
-S o Resets the flag for the operator panel.
-T threshold=value
Modifies the specified temperature thresholds to the given values. The valid
values for the [threshold] parameter are:
lowarn The low-temperature warning threshold.
hiwarn The high-temperature warning threshold.
The value parameter is a temperature in degrees C.
Examples
v To display the status of all bypass cards on enclosure0, give the command:
ssaencl -l enclosure0 -b
v To display the status and VPD of the controller card in enclosure0, give the
command:
ssaencl -l enclosure0 -c -v
v To modify the ID for enclosure0 to R2D2, give the command:
ssaencl -l enclosure0 -I R2D2
v To display the contents of disk bay (slot) 8 in enclosure0, give the command:
ssaencl -l enclosure0 -d 8
Chapter 16. Using the SSA Command Line Utilities 357
|
|
|
|
|
|
||
||
||
Przeglądanie stron 376
1 2 ... 372 373 374 375 376 377 378 379 380 381 382 ... 530 531

Komentarze do niniejszej Instrukcji

Brak uwag