Compex-systems Advanced SerialRAID Adapters SA33-3285-02 Instrukcja Użytkownika Strona 221

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 531
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 220
Failure of a Primary Disk Drive in a Dual-Host System: Figure 34 shows a
dual-host system in which the primary disk drive of a RAID-1 array has failed.
Because both adapters can still detect the secondary disk drive of the array, the Split
Array Resolution flag is automatically set to Secondary, and I/O operations continue.
The array is in the Exposed or Degraded state. When the primary disk drive is
reconnected, it is resynchronized from the secondary disk drive, and the Split Array
Resolution flag is automatically set to Primary.
Secondary 1
Split Array Resolution
= Primary
System 1
SSA Adapter
Primary 1
System 2
SSA Adapter
Figure 34. RAID-1 Disk Drive Failure
Chapter 8. Split-Site Management 201
Przeglądanie stron 220
1 2 ... 216 217 218 219 220 221 222 223 224 225 226 ... 530 531

Komentarze do niniejszej Instrukcji

Brak uwag