Dual-Host System with Primary Disk Drive Missing
Figure 30 shows a dual-host system that has just been switched on. The system
contains a RAID-1 array whose primary disk drive is missing. The array remains online,
but in the Exposed state until one of the following occurs:
v The missing primary disk drive becomes available again before a write operation to
the array occurs. Under this condition, the restored disk drive is returned as the array
primary disk drive, and the array returns to the Good state.
v A write operation to the array occurs before the missing primary disk drive becomes
available again. Under this condition:
If a hot spare disk drive is available, that hot spare disk drive automatically
becomes the new primary disk drive, and the array goes into the Rebuilding state.
If the missing primary disk drive then becomes available again, it is rejected.
If, after the write operation occurs, no hot spare disk drive is available, the array
enters the Degraded state. If the missing primary disk drive then becomes
available again, it is rejected.
Secondary 1
Split Array Resolution
= Primary
System 1
SSA Adapter
Primary 1
System 2
SSA Adapter
Figure 30. Dual-Host System with Primary Disk Drive Missing
Chapter 8. Split-Site Management 197
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Przeglądanie stron 216
1 2 ... 212 213 214 215 216 217 218 219 220 221 222 ... 530 531